The full of slab mesh reinforcement specification as below:
![]() |
|||||
REINFORCING MESH TO AS/NZS4671:2001 / RIBBED SQUARE MESH 6.0 X 2.4 METRES | |||||
Code | STD UNIT | LONGITUDINAL WIRES | CROSS WIRES | MASS / KG | |
SL52 | 6 x 2.4m Sheet | 10 x4.77 @ 200 + 4 x 4.00 @ 100 | 30 x 4.77 @ 200 | 21 | |
SL62 | 6 x 2.4m Sheet | 10 x 6.00 @ 200 + 4 x 4.24 @ 100 | 30 x 6.00 @ 200 | 33 | |
SL72 | 6 x 2.4m Sheet | 10 x 6.75 @ 200 + 4 x 4.77 @ 100 | 30 x 6.75 @ 200 | 41 | |
SL82 | 6 x 2.4m Sheet | 10 x 7.60 @ 200 + 4 x 5.37 @ 100 | 30 x 7.60 @ 200 | 52 | |
SL92 | 6 x 2.4m Sheet | 10 x 8.60 @ 200 + 4 x 6.00 @ 100 | 30 x 8.60 @ 200 | 66 | |
SL102 | 6 x 2.4m Sheet | 10 x 9.50 @ 200 + 4 x 6.75 @ 100 | 30 x 9.50 @ 200 | 80 | |
SL81 | 6 x 2.4m Sheet | 25 x 7.60 @ 100 | 60 x 7.60 @ 100 | 105 | |
![]() |
|||||
SQUARE MESH 300 X 300 SPACING TO AS/NZS4671:2001 | |||||
Code | STD UNIT | LONGITUDINAL WIRES | CROSS WIRES | MASS / KG | |
SL53 | 6 x 2.4m Sheet | 6 x 5.00 @ 300 | 20 x 5.00 @ 300 | 14 | |
SL63 | 6 x 2.4m Sheet | 6 x 5.00 @ 300 | 20 x 5.00 @ 300 | 21 | |
NL= Number of longitudinal bars PL= pitch of longitudinal bars dL= diameter of longitudinal bars NC=Number of transverse bars PC=Pitch of transverse bars dC=Diameter of transverse bars |
L= length of longitudinal bar B=Length of transverse bar u1=Overhang of longitudinal bars u2=Overhang of longitudinal bars u3=Overhang of transverse bars u4= overhang of transverse bars |
What is the material of the slab mesh reinforcement?
We adopt R250N,D500L,D500N,D300E,D500E as material to make the slab mesh reinforcement, especially D300E and D500E is seismic grade.
Firstly,Purchase wire rod from steel factory | Secondly,Test the raw material tensile strength |
![]() |
![]() |
Thirdly,drawing wire diameter as per contract | Fourthly,Straight and Cutting wire as per contract |
![]() |
![]() |
Fifthly,The reinforcement steel mesh welded by automatic and electric resistance machine | After finished producing,the reinforcement steel mesh has a good condition storage. |
![]() |
![]() |
Clearly and visible notches | Firmly and strong solid joint |
![]() |
![]() |
Messured wire diameter of reinforcement steel mesh | Messured mesh space of reinfocement steel mesh |
![]() |
![]() |
Steel pallet for reinforcing mesh size 2.4m *6m | Loading container for reinforcing mesh sheet:2.4m *6m |
Type of analysis | Chemical composition,% max | |||||||
All grades | Carbon equivalent value(Ceq)for standard grades | |||||||
C | P | S | 250N | 500L | 500N | 300E | 500E | |
Cast analysis | 0.22 | 0.050 | 0.050 | 0.43 | 0.39 | 0.44 | 0.43 | 0.49 |
Products analysis | 0.24 | 0.055 | 0.055 | 0.45 | 0.41 | 0.46 | 0.45 | 0.51 |
Property | 250N (Note1) |
500L (Note1) |
500N | 300E (Seismic) |
500E (Seismic) |
Type of specified value |
Yield Stress(Mpa) RekL RekU |
≥250 --------- |
≥500 ≤750 |
≥500 ≤650 |
≥300 ≤380 |
≥500 ≤600 |
CvL:p=0.95 CvU:p=0.05 |
Ratio Rm/Re | ≥1.08 --------- |
≥1.03 ----------- |
≥1.08 -------- |
≥1.15 ≤1.50 |
≥1.15 ≤1.40 |
CvL:p=0.90 CvU:p=0.10 |
Unitform Elogation Agt(%) | ≥5.0 | ≥1.5 | ≥5.0 | ≥15.0 | ≥10.0 | CvL:p=0.90 |