Basic Info.
Model NO.
SL62/SL72/SL82/SL92/SL102/RL718/RL818/RL918/RL1018
After-sales Service
24hours Online
Material
Low-Carbon Iron Wire
Application
Construction Wire Mesh, Protecting Mesh
Certification
ISO9001, CE
Transport Package
Bundle &Pallet
Product Description
SL51.5/ SL41.5 construction reinforcement mesh by AS-NZS 4671-2001 standard
Construction reinforcement mesh was made by plain steel wire.It main used on building construction complied with standard AS NZS 4671-2001.
The material is 250N,500N,500L,300E,500E ,the mesh size is 150x150mm, wire diameter is 5.3mm and 4.0mm and the overhang length is in both sides. These specificate is very pouplar in New Zealand civil engineering field.
More features of construction reinforcement mesh and ours as below:
- high quality raw material
- electric resistance welding machine made it which has firmly solder join,size precision,and appearance good-looking
- Professional management team
- Complete QC rules and regulations
- A full of laboratory testing instruments
Packing and shipment of construction reinforcement mesh by AS-NZS 4671-2001 standard:
Advantage of construction reinforcement mesh by AS-NZS 4671-2001 standard:
- Save 30% of steel bar dosages
- Reduce 50%-70% work time,improve construction progress and shorten construction period.
- Cut down 5%-10% construction cost
- Used widely,it has a good market development prospects.
How can we measure our construction reinforcement mesh:
| |
| |
Tensile stregth test of construction reinforcement mesh as per contract | Wire diameter of construction reinforcement mesh messured as per contract |
| |
| |
Overhang of construction reinforcement mesh messured | Mesh spaces of construction reinforcement mesh messured, |
| |
Width of construction reinforcement mesh messured as per contract | Lengh of construction reinforcement mesh messured as per contract |
Application of construction reinforcement mesh by AS-NZS 4671-2001 standard:
building construction,highway road reinforcement,bridge support,tunnel reinforced,mine and coal reinfocing
The production process of construction reinforcement mesh by AS-NZS 4671-2001 standard:
The specification of construction reinforcement mesh by AS-NZS 4671-2001 standard as below:
Mesh Type and reference number | Longitudinal bars | Cross-bars | Mass for 6 x2.4 m sheets | Cross-sectional area/m width |
No.x dia., mm | Pitch@mm | No.x dia., mm | Pitch@mm | Unit area kg/sqm | Sheet, kg | Long'l bars sqmm/m | Cross bars sqmm/m |
Squre,with edge side-lapping bars |
SL102 | 10x9.5+ 4x6.75 | 200 100 | 30x9.5 | 200 | 5.6 | 80 | 354 | 354 |
SL92 | 10X8.6+ 4X6.0 | 200 100 | 30x8.6 | 200 | 4.6 | 66 | 290 | 290 |
SL82 | 10x7.6+ 4x6.0 | 200 100 | 30x7.6 | 200 | 3.6 | 52 | 227 | 227 |
SL72 | 10x6.75+ 4x5.0 | 200 100 | 30x6.75 | 200 | 2.8 | 41 | 179 | 179 |
SL62 | 10x6.0+ 4x5.0 | 200 100 | 30x6.0 | 200 | 2.2 | 33 | 141 | 141 |
Squre,without edge side-lapping bars |
SL81 | 25X7.6 | 100 | 60x7.6 | 100 | 7.1 | 105 | 454 | 454 |
Product Code | Std Unit | Longitudinal Wires | Cross Wires | Mass(kg) | Dimensions(m) |
SL62UTE | Sheet | 8×6@200 | 20×6@200 | 18 | 4×2 |
SL72UTE | Sheet | 8×6.75@200 | 20×6.75@200 | 23 | 4×2 |
SL82UTE | Sheet | 8×7.6@200 | 20×7.6@200 | 30 | 4×2 |
Rectangular Reinforcing Mesh 2.4m*6m=14.4sqm |
Code | Cross wire | Longwire mm | Mass/sheetkg | Quantityin pack |
Pitch@mm | No. x dia., mm | Pitch@mm | No. x dia., mm |
RL718 | 7.60 @ 200 | 30 x7.6 | 6.75 @ 100 | 25 x 7.6 | 68 | 20 |
RL818 | 7.60 @ 200 | 30 x7.6 | 7.60 @ 100 | 25 x7.6 | 79 | 20 |
RL918 | 7.60 @ 200 | 30 x7.6 | 8.55 @ 100 | 25 x 8.55 | 93 | 20 |
RL1018 | 7.60 @ 200 | 30 x7.6 | 9.50 @ 100 | 25 x9.5 | 109 | 15 |
RL1118 | 7.60 @ 200 | 30 x7.6 | 10.65 @ 100 | 25 x10.65 | 131 | 15 |
RL1218 | 7.60 @ 200 | 30 x7.6 | 11.90 @ 100 | 25 x11.9 | 157 | 10 |
Reinforcing Mesh |
Code | wire diameter | aperture | edge open | width | length | weight per sheet(kgs) |
F62 | 5mm | 200*200mm | 200mm | 2.4m | 6m | 20.92 |
F72 | 6mm | 200*200mm | 200mm | 2.4m | 6m | 30.12 |
F82 | 7mm | 200*200mm | 200mm | 2.4m | 6m | 41 |
F92 | 8mm | 200*200mm | 200mm | 2.4m | 6m | 53.55 |
concrete reinforcing mesh specification |
Mesh Type and reference number | Longitudinal bars | Cross-bars | Mass for 6x2.4m sheets | Cross-sectional area/m width |
No. x dia., mm | Pitch,@mm | No. x dia., mm | Pitch,@mm | Unit area,kg/sqm | Sheet,kg | Long'l bars,sqmm/m | Cross bars,sqmm/m |
Structural and skatch |
|
SE92 | 13 X9.0 | 200 | 30 X9.0 | 200 | 5.0 | 75 | 318 | 318 |
SE82 | 13 X8.0 | 200 | 30 X8.0 | 200 | 3.9 | 59 | 251 | 251 |
SE72 | 13 X7.0 | 200 | 30 X7.0 | 200 | 3.0 | 45 | 192 | 192 |
SE62 | 13 X6.0 | 200 | 30 X6.0 | 200 | 2.2 | 33 | 141 | 141 |
Non-structural |
|
SL51.5 | 17 X5.3 | 150 | 40 X5.3 | 150 | 2.2 | 32 | 147 | 147 |
SL41.5 | 17 X4.0 | 150 | 40 X4.0 | 150 | 1.3 | 19 | 84 | 84 |
REINFORCING MESH TO AS/NZS4671:2001 / TRENCH MESH |
Code | STD UNIT | LONGITUDINAL WIRES | CROSS WIRES | MASS / KG |
L8TM200 | 6 Metre | 3 x 7.60 @ 100 | 4.00 @ 300 | 6.8 |
L8TM300 | 6 Metre | 4 x 7.60 @ 100 | 4.00 @ 300 | 9.2 |
L8TM400 | 6 Metre | 5 x 7.60 @ 100 | 4.00 @ 300 | 11.6 |
L8TM500 | 6 Metre | 6 x 7.60 @ 100 | 4.00 @ 300 | 13.9 |
L8TM600 | 6 Metre | 3 x 7.60 @ 100 | 4.00 @ 300 | 15.9 |
L8TM2400 | 6 Metre | 25 x 7.60 @ 100 | 4.00 @ 300 | 72 |
L11TM200 | 6 Metre | 3 x 10.70 @ 100 | 4.77 @ 300 | 13 |
L11TM300 | 6 Metre | 4 x 10.70 @ 100 | 4.77 @ 300 | 17.7 |
L11TM400 | 6 Metre | 5 x 10.70 @ 100 | 4.77 @ 300 | 22.3 |
L11TM500 | 6 Metre | 6 x 10.70 @ 100 | 4.77 @ 300 | 26.8 |
L11TM600 | 6 Metre | 7 x 10.70 @ 100 | 4.77 @ 300 | 34 |
L11TM2300 | 6 Metre | 24 x 10.70 @ 100 | 4.77 @ 300 | 107.1 |
L12TM200 | 6 Metre | 3 X 11.90 @ 100 | 4.77 @ 300 | 16.3 |
L12TM300 | 6 Metre | 4 X 11.90 @ 100 | 4.77 @ 300 | 21.8 |
L12TM400 | 6 Metre | 5 X 11.90 @ 100 | 4.77 @ 300 | 27.3 |
L12TM500 | 6 Metre | 6 X 11.90 @ 100 | 4.77 @ 300 | 32.8 |
L12TM600 | 6 Metre | 7 X 11.90 @ 100 | 4.77 @ 300 | 38.1 |
Model | Pitch/ certres | Wire dia. (mm) | Length (mm) | Width (mm) | Newt cover(sqm) | Heyou reinforcing item | Cross section sqmm/m | Mass per sqm kg/sqm | No.of Longitudinal wire | No. of Cross Wire | Overhangs of Longitudianal wire | Overhangs of Cross wire | Weight(kg) |
668 | 150 | 4.0 | 4650 | 1970 | 7.525 | 668L | 83.8 | 1.315 | 14 | 31 | 75/75 | 10/10 | 12.44 |
665 | 150 | 5.3 | 4650 | 1970 | 7.525 | 665L | 147.1 | 2.309 | 14 | 31 | 75/75 | 10/10 | 21.85 |
663 | 150 | 6.3 | 4650 | 1970 | 7.525 | 663L | 207.8 | 3.263 | 14 | 31 | 75/75 | 10/10 | 30.87 |
665 | 150 | 5.3 | 6150 | 2420 | 12.760 | 665E | 147.1 | 2.309 | 17 | 41 | 75/75 | 10/10 | 35.29 |
663 | 150 | 6.3 | 6150 | 2420 | 12.760 | 663E | 207.8 | 3.263 | 17 | 41 | 75/75 | 10/10 | 49.86 |
662 | 150 | 7.1 | 6150 | 2420 | 12.760 | 662E | 263.9 | 4.144 | 17 | 41 | 75/75 | 10/10 | 63.33 |
661 | 150 | 7.5 | 6150 | 2420 | 12.76 | 661E | 294.5 | 4.624 | 17 | 41 | 75/75 | 10/10 | 70.67 |
300 Centres of hard drawn mesh | | | | | | | |
668 | 300 | 5.6 | 4950 | 2220 | 10.08 | 84/10 | 82.1 | 1.289 | 4*5.6mm+4*4.0mm | 19 | 25/25 | 10/10 | 15.85 |
665 | 300 | 7.5 | 4950 | 2220 | 10.08 | 147/10 | 147.3 | 2.312 | 6*7.5mm+4*5.3mm | 19 | 25/25 | 10/10 | 28.36 |
665 | 200 | 6.1 | 5050 | 2020 | 8.312 | SE62 RES | 146.1 | 2.294 | 11 | 26 | 25/25 | 10/10 | 24.79 |
665 | 200 | 6.1 | 5850 | 2420 | 11.93 | SE62 | 146.1 | 2.294 | 13 | 30 | 25/25 | 10/10 | 34.10 |
665 | 300 | 7.5 | 6050 | 2420 | 11.58 | SE73 | 147.3 | 2.312 | 9 | 21 | 25/25 | 10/10 | 36.51 |
665 | 300 | 7.5 | 5000 | 2270 | 10.08 | SE73DE | 147.3 | 2.312 | 8*7.5mm+2*5.5mm | 19 | 7.5mm:25/25 5.5mm:25/25 | 10/10 | 30.69 |
664 | 200 | 7.0 | 5650 | 2220 | 10.432 | SE72 | 192.4 | 3.02 | 12 | 29 | 25/25 | 10/10 | 39.93 |
662 | 200 | 8.0 | 5650 | 2220 | 10.432 | SE82 | 251.3 | 3.946 | 12 | 29 | 25/25 | 10/10 | 52.16 |
661 | 200 | 9.0 | 6100 | 2420 | 12.76 | SE92 | 318.0 | 4.99 | 12 | 29 | 25/25 | 10/10 | 71.65 |
3.Each sheet of reinforcing mesh panel shall include number of bars,pitch,length,width, and overhang dimensions. And the bar arrangement of reinforcing mesh panel has single bars,twin bars or combination of single bars and twin bars.
4.The technical data of reinforcing mesh panle is contained composition and characteristic mechanical porperties of reinforcing steels.
4.1.1
Table1
Composition of reinforcing steels
Type of analysis | Chemical composition,% max |
All grades | Carbon equivalent value(Ceq)for standard grades |
C | P | S | 250N | 500L | 500N | 300E | 500E |
Cast analysis | 0.22 | 0.050 | 0.050 | 0.43 | 0.39 | 0.44 | 0.43 | 0.49 |
Products analysis | 0.24 | 0.055 | 0.055 | 0.45 | 0.41 | 0.46 | 0.45 | 0.51 |
4.1.2
Table 2
Characteristic mechanical properties of reinforcing steels
Property | 250N (Note1) | 500L (Note1) | 500N | 300E (Seismic) | 500E (Seismic) | Type of specified value |
Yield Stress(Mpa) RekL RekU | ≥250 --------- | ≥500 ≤750 | ≥500 ≤650 | ≥300 ≤380 | ≥500 ≤600 | CvL:p=0.95 CvU:p=0.05 |
Ratio Rm/Re | ≥1.08 --------- | ≥1.03 ----------- | ≥1.08 -------- | ≥1.15 ≤1.50 | ≥1.15 ≤1.40 | CvL:p=0.90 CvU:p=0.10 |
Unitform Elogation Agt(%) | ≥5.0 | ≥1.5 | ≥5.0 | ≥15.0 | ≥10.0 | CvL:p=0.90 |
Notes:
- Grade 250N is supplied as plain round reinforcing steel complying with AS 3679.1,exceptthe tolerance of the diameter and roundness dosen't apply it.
- For 500L steel bars,only requriement for wire diameter is less than 5.0mm is RekL≥500
Secondly,the panel size tolerances meassure way as:
- Panel Size dimensions≤6m in length,there is 40mm tolerances.
- Panel size dimensions>6m in length,the tolerance is ±0.7%
- Wire diameter and mesh size measure and weld shear resistance test conformance to AS NZS 4761-2001 and as per contract.
- Weigh the each bundle weight to calculate each panel weight.
Company Profile
Address:
17-1-202, No. 1, Changjiang Road, Shijiangzhuang, Shijiazhuang, Hebei, China
Business Type:
Manufacturer/Factory
Business Range:
Auto, Motorcycle Parts & Accessories, Construction & Decoration, Industrial Equipment & Components, Instruments & Meters, Light Industry & Daily Use, Metallurgy, Mineral & Energy, Security & Protection, Sporting Goods & Recreation, Tools & Hardware, Transportation
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Heyou Wire Mesh was established in 2009 year, which is a professional manufactory for reinforcement mesh, reinforcing mesh, reinforced mesh. Heyou Wire Mesh can produce National Standard reinforcing mesh, Australian/New Zealand Standard AS-NZS4671-2001 Reinforcement Mesh, British Standard BS4483 fabric reinforcement/reinforced mesh, Osterreichische Norm B4200-7 Grids and reinforcing meshes, Germany Standard DIN488 SD Reinforcing Mesh, Normes Francaises NFA35-016 Steel Rebar Mesh and Swiss Standard SIA 16211 S550 Reinforcement Wire Mesh. Our production capacity is 2000tons per month. Heyou factory has 8 workshops and covers 20000sqm area, with advanced international standard production line and equipments.
We have a professional production team, a stictly set of Production management system and a complete set of QC system to ensure the products quality. We select the raw material from the steel factory which has high reputation in our field. When the material is coming to our factory, we will send the sample of the raw material to our laboratory in order to conform it as per contract requirement. During production, our quality inspector will be meassured in every link such after drawing wire, cutting wire, after welding. Although we inspected weld shearing, tensile strength, yeild strength of the whole mesh panel. About the Quality controled, we always adhere to the integrity of the fundamental, strategy of growth through quality.
Heyou Wire Mesh built and develped the cooperation relationship with new and old business at home and abroad continuosly with our mission of offering products exactly meeting your needs. Heyou has competitive price, rich experiences, efficiency and reliability allow us to gain trust and praise from clients worldwide. We sincerely welcome you to our factorym, inspect our capacity and start business cooperation based on mututal benefit ad double win strategy!
We can produce wire mesh according to the customer′s requirements. We warmly welcome your visit and business inquiry.